Abb library is a web tool for searching for documents related. Nulec technical manual nsr011029 nseries automatic circuit recloser nulec technical manual w01194 wseries automatic circuit recloser 3. Product guide osm automatic circuit recloser 15kv 27kv 38kv models introduction voltage is measured on each bushing and current is measured on each phase of the osm recloser using capacitively coupled voltage sensors and current transformers. It is a simple and cost effective solution designed for easy maintenance and future upgradeability. An overcurrent fault would indicate a line to line class fault, which can be confirmed by negative phase sequence overcurrent protection, whereas an earth fault can indicate a line to ground or double line to. Useries solid dielectric automatic circuit recloser. Page 2 of 9 standard work practice sp0233 ver 3 ergon energy corporation limited abn 50 087 646 062 ergon energy queensland pty ltd abn 11 121 177 802 sp0506. The useries solid dielectric automatic circuit recloser also known as a circuit breaker represents nulec industries commitment to improved products and ongoing product development. Automatic circuit reclosers and highvoltage circuit breakers provide alternate means for distribution circuit protection. Low voltage devices recloser controller all types meet the requirements of the emc. Download documents for nulec nseries mv polemounted automatic circuit reclosers. Form 6 microprocessorbased pole mount recloser control installation and operation instructions 4 figure 2. A recloser is a circuit breaker which can be closed automatically after the breaker has been opened because of electric fault.
A recloser without communications capabilities could be a problem at this time, no alerts are sent to operators. Download documents for nulec wseries mv polemounted automatic circuit reclosers. Personal computer based on software package supports online and offline programming, monitoring, measuring and control of recloser via rs232 port. Form 6 microprocessorbased service information pole mount. Eseries threephase recloser with advc controller medium. The recloser monitors line current and voltage without the need for additional measurement devices. You can download these technical publications and other technical information from. Useries threephase recloser wseries singlephase recloser. Intelligent and efficient network power protection from entry level to scaleable runtime. Upon receipt, inspect the shipping container for signs for damage. Controller will be controlling the opening and closings of breaker as per line parameters sensed by respective cts and pts in system. This smart grid solution eliminates momentary outages for customers on the main feeder by only blinking the affected laterals. The nseries automatic circuit recloser acr is a stateoftheart electronically controlled outdoor, pole mounted, three phase recloser.
Ideal ups for servers, pointofsale, routers, switches, hubs and other network devices. The nseries gas insulated automatic circuit recloser is designed around vacuum interrupters contained in a fully welded and sealed 316 grade stainless steel enclosure. Form 6 pole mount recloser control is accessible from both the front and back of the cabinet. Unpack the recloser and inspect it thoroughly for damage incurred during shipment. Download fulltext pdf download fulltext pdf optimization of recloser placement to improve reliability by genetic algorithm article pdf available in energy and power engineering 31. Substation primary plant and secondary systems field testing swp sp0508. Once the impedance tests are completed download results into proactiv database. Comparison of recloser and breaker standards eaton. Nulec nseries documents and downloads schneider electric. The noja power recloser app is designed to interface to noja power rc10 recloser control and communications cubicles via any tcpip connection. Optimization of recloser placement to improve reliability by. Recloser status nonreclosing alternate profile battery test voltage and current adding intelligent singlephase cooper power systems spear reclosers and controls to distribution lines can meet todays system reliability needs and easily transition for future smart grid applications. Recloser controller the operator control panel is provided with a large backlit lcd display and keypad to provide fast navigation and local control.
If the recloser closes onto a fault, it is likely that the fault is a secondary class of fault, vegetation contact or equipment failure. We have cooper form 6 electronic recloser manual epub, djvu, doc, pdf, txt formats. Form 6 microprocessorbased service information pole. Schneider electric nulec industries 12kv, 24kv and 36kv reclosers n15, n27, w27 and n38. This commissioning test sheet covers the checking, testing and commissioning of all replacement or new installations of nulec pole mounted reclosers before energisation. Technical specification for pole mounted remotely controllable automatic circuit reclosers for single wire earth return swer distribution systems page 3 of 32 specification ets060702 ver 4 ergon energy corporation limited abn 50 087 646 062 automatically trip and lock out the recloser if the sf6 pressure falls to a value where any. The pole top circuit breaker is one of the manufacturers family of outdoor circuit breakers optimised for remote control and automation schemes. Because many faults in power systems fix themselves after they happen, the installation of recloser ensures more continuity of power and higher availability for electricity supply to the load.
Schneider electric nulec industries 12kv, 24kv and 36kv. This instruction manual covers information related to the recloser switch units and the. The patented combined insulation makes them an environmental friendly option. A service parts list, keyed to explodedview drawings of the recloser is included at the back of the manual. When the preprogrammed number of recloser operations is reached, the controller opens the sectionaliser during the recloser dead time to isolate the downstream fault. Recloser simple english wikipedia, the free encyclopedia. The problem could be more complicate if a recloser is outside of the downtown. If damage is discovered, file a claim with carrier. All telemetry communication can be supported with dnp3. Cold load pick up characteristic prevents the recloser to trip from the expected transient current when manual closing of auto recloser locally or remotely is applied for the healthy system. Solid insulated vacuum recloser for power distribution system. Detailed description of recloser acr 120 for 12kv vim vacuum. Schneider recloser load break switch sectionaliser swp check this is the latest process zone version before use. Sf gas insulated vacuum recloser for power distribution.
Hughes power system autoreclosers, recloser auto recloser. Substation projects sites substation ied management recloser nulec. The recloser is completely assembled, tested, and inspected at the factory. It offers a flexible phase and ground overcurrent protection for. How the electric utility industry generates and delivers power to its customers covering basics, delivery, safety and generation.
The panel menus are presented in descriptive text which provides ease of use for operators and reduces the learning curve. When the usb wifi router accessory is fitted to enable wifi capability the recloser app will connect to the control to provide remote control and interrogation capability. Latest evolution of leading automatic circuit recloser firmware enables seamless control of builtin communication features of latest controllers and provides broken conductor, higher resolution sensitive earth fault and admittanceprotection to meet special requirements of highimpedance distribution networksbrisbane, qld, australia march 21, 2017 electrical switchgear. Long lifetime, low maintenance equipment reduces lifetime cost. This is a useful tool for electricity utility linesman to. Abb library is a web tool for searching for documents related to abb products and services. Swedish manufacturer of reclosers and other medium voltage outdoor and indoor switchgear products. Fxd microprocessorbased recloser control product features the fxd recloser control is a cost effective solution providing basic functionality that are configurable and can be used for any protective application. The triplesingle type sdr vacuum recloser consists of three singlephase switch units, each mounted in a separate tank and controlled from a common controller. Nseries useries wseries rlseries with this software, engineers perform tasks such as analysing the history of events from each device to develop strategies for maintenance. Substation rack mount pcd relay the 1527 kv ovr1 singlephase recloser and icd controls compact, lightweight design makes it easy to install and. Technical specification for pole mounted controllable. The recloser functions, settings and data records are programmable and readable with pc or remote communi cation. The vacuum recloser consists of two main components.
Insulation resistance for a singlephase recloser 1 ensure the recloser is opened prior to conducting the ir test. Rc controller noja power recloser switchgear engineers. The vipersp is designed for auto matic or manual operation providing overcurrent protection for single phase systems through 38kv maxi. Latest evolution of leading automatic circuit recloser. The enclosure is filled with sulphur hexaflouride sf 6 gas, which has excellent electrical insulating properties, resulting in a compact and low maintenance device.
Eatons cooper power systems catalog reclosers and controls. Pdf 143ben 102uen 117uen 009ben 112ben se721 recloser rfpp. Validity note this document is valid for the u and wseries remotely controlled and monitored automatic circuit recloser acr which consists of the u and wseries automatic circuit recloser acr combined with an advc controller advc. Available in 1538 kv, the ovr3sp utilizes three individual singlephase recloser poles for flexible mounting options. A recloser is a special type of circuit breaker that automatically recloses after a fault has occurred in overhead power lines. In addition to automatic circuit reclosers, the schneider electric family of. Download catalogue recloser nulec schneider 27kv useries u27. Download fulltext pdf download fulltext pdf optimization of recloser placement to improve reliability by genetic algorithm article pdf available in energy and.
The test is performed automatically by increasing the current flow through the reclosers operating coil until operation begins. Sdi 214 schneider electric nulec industries 12kv, 24kv and 36kv reclosers n15. Download catalogue recloser nulec schneider 27kv useries. Downloading logs, profiles, oscillograms, settings. The recloser test set is able to perform, display and record the following tests. Minimum response time of 45ms specifies the fastest clearing time for the line protection. To accomplish this it senses the threephase current and voltage to count the number of recloser trip operations. Nseries automatic circuit recloser nulec technical manual w01194 wseries automatic circuit recloser. Solid insulated vacuum recloser for power distribution. The nseries three phase pole mounted auto recloser or circuit breaker was developed to achieve optimum performance and reliability, making use of the latest technology in vacuum interrupters housed in an sf6 gas filled tank. They are equipped with sensors and intelligent electronic devices specially designed to protect lines and customer, isolating automatically faults and restoring the service if the fault has been cleared.
If the the control shuts down due to low battery voltage before ac power is restored, and. It is good condition when accepted by the carrier for shipment. Highly efficient 20 to 100 kw 480 v, 10 to 150 kw 400 v, and 10 to 50 kw. Procedures for testing the recloser and control together are. Percentage of companies using indices 49 companies responded. This is a useful tool for electricity utility linesman to control and. Perform a motion analyzer test of the unit for a close, reclose, trip and tripfree. Basic fault finding on reclosers and load break switches using ptcc. Schneider recloser load break switch sectionaliser swp. Proven industrial ups power protection for control applications and harsh environments. The fxd recloser control is the latest design in the series of fully integrated controls developed by cooper power systems, ready for the smart grid. When a fault occurs in a overhead power line a typical circuit breaker will disconnect its contacts disabling the line while with a recloser the. Minimum trip current this test determines the reclosers minimum operating point usually two times the rating of the coil. Optimization of recloser placement to improve reliability.
This data can then be used for forward planning and optimization of existing feeders. Nseries useries wseries rlseries with this software, engineers perform tasks such as analysing the history of events from each device to. Nulec wseries documents and downloads schneider electric. The time to reestablish the power should be long due to the. The fxd recloser control is the latest design in the series of fully. Wsos 5 windows switchgear operating system 5 is a software package that allows the remote control and monitoring of pole mounted auto reclosers and load break switches sectionalisers. It provides the features of a traditional recloser, plus the benefits of up to date design optimised for automation, remote control and monitoring, now or in. If the line parameters varies due to various faults on system controller will take respective action along with recloser openings to clear faults.
240 217 434 874 773 819 365 367 887 1191 1406 760 905 1155 287 911 981 1307 141 975 1236 1288 263 1 1078 586 426 372 456 1142